Throughput per hour,
native (uncompressed): |
LTO Gen 2 (18 drives,
3,600 MB/sec) - up to 2 TB/hr
|
|
Capacity, native
(uncompressed): |
(maximum
configurations 577 cartridges) LTO Gen 2 (200
GB/cart) - 115 TB
|
|
Number of cartridge
slots: |
30-577 slots
Base module: 30-50 LTO cartridge slots
Drive expansion module: 90 additional slots
Cartridge expansion module: 130 additional slots
|
|
Number of tape drives
/ types: |
1-18 LTO Ultrium
Generation 2
|
|
Cartridge access port
(CAP): |
Base module,
5-cartridge capacity
Drive expansion module, 10-cartridge capacity
|
|
Mean exchanges / swaps
between failure (MEBF/MSBF): |
>2,000,000
|
|
Mean time to repair (MTTR): |
<30 min
|
|
Non-disruptive
serviceability: |
Hot-swappable drives,
Ethernet and serial ports for diagnostics and
reporting. Redundant hot-swappable power supplies
with redundant fans.
|
|
Supported host
platforms: |
UNIX, Windows NT
|
|
Robotics control
interfaces: |
Small Computer System
Interface (SCSI) - 3 media changer command set
high-voltage differential (default), low-voltage
differential and 2-Gb Fibre Channel
|
|
Any Cartridge Any
Slot™ technology: |
Simultaneous
non-partitioned support of multiple tape and media
types
|
|
SNMP: |
Embedded SNMP agent
that enables remote reporting, monitoring and
notification via standard Ethernet connection
|
|
Digital vision system: |
Unique digital vision
camera system that performs continuous calibration
and reads bar codes
|
|
Operator panel: |
Optional user-friendly
configuration and diagnostic controls, status
display and viewing window
|
|
Automatic clean: |
Dedicated cleaning
cartridge slot for tape drive cleaning by library or
software command
|
|
Automatic self
discovery: |
Self-configuring for
cells, drives and cartridge access ports
|
|
Continuous automation
calibration: |
No periodic
maintenance or alignment required
|
|
Height: |
(Minimum
configuration)
14.00 in (35.6 cm)
|
|
Depth: |
27.5 in (69.9 cm)
without cabinets
|
|
Width: |
19.0 in (48.3 cm)
|
|
Unit height: |
8u*
|
|
Weight: |
75.8 lb (34.3 kg)
|
|
Height: |
14.0 in (35.6 cm)
|
|
Depth: |
27.5 in (69.9 cm)
|
|
Width: |
19.0 in (48.3 cm)
|
|
Unit height: |
8u*
|
|
Weight: |
58.4 lb (26.6 kg)
|
|
Height: |
14.0 in (35.6 cm)
|
|
Depth: |
27.5 iin (69.9 cm)
|
|
Width: |
19.0 in (48.3 cm)
|
|
Unit height: |
8u*
|
|
Weight: |
44.2 lb (20.1 kg)
|
|
Temperature
(operating): |
+59° to + 90° F (+15°
to 32° C)
|
|
Temperature
(non-operating): |
+50° to + 104° F (+10°
to 40° C )
|
|
Relative humidity
(operating): |
20%–80%
|
|
Relative humidity
(non-operating): |
10%–95%
|
|
Voltage: |
100–127 VAC, 200–240
VAC @ 50–60 Hz single phase (auto-ranging)
|
|
Library (operating
maximum continuous - not peak): |
1.0 A @ 120 V, 0.5 A @
240 V, 410 BTU/hr
|
|
Drives: |
Drive power
consumption varies. Refer to individual drive
specifications
|
|
Power
consumption/dissipation: |
Single-phase
configurations:
24 amps per phase @ 180 VAC (line to neutral or line
to line) 13.0kW,
40 amps per phase @ 180 VAC (line to line) 13.0kW,
44,380 BTU/hr
|
|
Electromagnetic
compliance: |
FCC (47 CFR 15,
Subpart B) Class A
CE (EN55022 Class A, EN55024, EN61000-3-2,
EN61000-3-3)
VCCI (CISPR 22) Class A
Canada (ICES-003) Class A
|
|
Safety: |
UL 1950
CAN/CSA 22.2 No. 950
EN60950
|
|
Immunity: |
European Union CE
immunity standards
|